Contrast-enhanced ultrasound examination of a stable functioning renal transplant. Pilot study

https://doi.org/10.24835/1607-0763-1588

Abstract

Objective. The lack of standardized protocols and reference values for quantitative parameters in contrast-enhanced ultrasound (CEUS) of stable functioning renal transplants limits its clinical application. This study aimed to analyze CEUS quantitative parameters in recipients with stable graft function and no significant pathology on protocol biopsy, as well as to assess inter-operator reproducibility.

Materials and Methods. An interventional prospective study was conducted (October 1, 2024 – March 1, 2025). 23 patients were enrolled. CEUS was performed by Resona 7 system (Mindray, China) with a convex probe (1.2–6 MHz) and SonoVue contrast agent (Bracco, Italy). Time-intensity curve (TIC) parameters were analyzed in: ROI1 (region of interest): cortex, ROI2: cortex between pyramids (renal columns), ROI3: pyramids, ROI4: combined ROI1+ROI2+ROI3. Parameters assessed: Ascending Slope (AS), Arrival Time (AT), Area Under the TIC Curve (AUC), Descending Slope (DS), mean TIC intensity (mTIC), Peak Intensity (PI), Rise Time (RT), Time-to-Peak (TTP), Wash-in Area Under the Curve (WiAUC), Perfusion Index (WiAUC/RT), Wash-out AUC (WoAUC). Analysis was performed using Contrast QA software (Mindray). Inter-operator reproducibility was evaluated via intraclass correlation coefficients (ICC) and Bland-Altman analysis (mean difference, limits of agreement).

Results. Mean TIC parameters (averaged between operators) were obtained for all ROIs. ROI1: excellent/good reproducibility for most parameters; moderate reproducibility for AS and DS (ICC 0.840 [0.662; 0.928] and 0.859 [0.697; 0.938]). ROI2: Excellent to good reproducibility; moderate for WiAUC (0.848 [0.678; 0.933]), RT (0.877 [0.733; 0.946]), WiAUC/RT (0.835 [0.628; 0.929]), AS (0.836 [0.653; 0.927]), and DS (0.777 [0.537; 0.899]). ROI3: Higher variability for WiAUC/RT (0.706 [0.418; 0.864]), AS (0.657 [0.351; 0.838]), and DS (0.752 [0.497; 0.887]). ROI4: Results comparable to ROI1.

Conclusion. This study is a crucial step toward standardizing CEUS for renal transplants. It establishes the first quantitative CEUS benchmarks for stable allografts without significant pathology on protocol biopsy. The low inter-operator variability supports the clinical feasibility of using absolute TIC parameters (comparison of normal vs dysfunctional grafts) across different ultrasound systems.

About the Authors

S. N. Larionova
Samara State Medical University
Russian Federation

Svetlana N. Larionova – Head of the Department of Ultrasound Diagnostics, Samara State Medical University; Assistant Professor, Department of Ultrasound Diagnostics, Samara State Medical University, Samara
https://orcid.org/0000-0001-5736-8656



N. I. Belavina
Moscow Clinical Science and Research Center 52 of Moscow Healthcare Department
Russian Federation

Natalya I. Belavina – Cand. of Sci. (Med.), doctor of the Department of Ultrasound and Functional Diagnostics, Moscow Clinical Science and Research Center 52, Moscow
http://orcid.org/0000-0003-2953-5570



N. N. Vetsheva
Russian Medical Academy of Continuous Professional Education of the Ministry of Healthcare of the Russian Federation
Russian Federation

Natalya N. Vetsheva – Doct. of Sci. (Med.), Professor at the Department of Ultrasound Diagnostics, Russian Medical Academy of Continuous Professional Education of the Ministry of Healthcare of the Russian Federation
http://orcid.org/0000-0002-9017-9432



R. B. Balter
Samara State Medical University
Russian Federation

Regina B. Balter – Doct. of Sci. (Med.), Head of the Department of Ultrasound Diagnostics, Institute of Postgraduate Education, Samara State Medical University, Samara
http://orcid.org/0000-0001-6724-0066



References

1. Kaballo M.A., Canney M., O'Kelly P. et al. A comparative analysis of survival of patients on dialysis and after kidney transplantation. Clin. Kidney J. 2018; 11: 389–393. https://doi.org/10.1093/ckj/sfx117

2. Redfield R.R., McCune K.R., Rao A. et al. Nature, timing, and severity of complications from ultrasound-guided percutaneous renal transplant biopsy. Transpl. Int. 2016; 29 (2): 167–172. https://doi.org/10.1111/tri.12660

3. Association of Clinical Research Organizations (ACRO) – Declaration of Helsinki of the World Medical Association [Electronic resource]. – URL: http://acto-russia.org/index.php?option=com_content&task=view&id=21 (25.04.2025) (In Russian)

4. Koo T.K., Li M.Y. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J. Chiropr. Med. 2016; 15 (2): 155–163. https://doi.org/10.1016/j.jcm.2016.02.012

5. Jimenez C., de Gracia R., Aguilera A. et al. In situ kidney insonation with microbubble contrast agents does not cause renal tissue damage in a porcine model. J. Ultrasound Med. 2008; 27: 1607–1615. https://doi.org/10.7863/jum.2008.27.11.1607

6. Sencha A.N. (ed.). Ultrasound examination using contrast agents. From simple to complex. Moscow: MEDpress-inform, 2021. 296 p. ISBN 978-5-00030-862-2 (In Russian)

7. Belavina N.I., Larionova S.N., Vetsheva N.N. et al. Contrast-enhanced ultrasound of kidney allograft with acute rejection: clinical case and review. Ultrasound and Functional Diagnostics. 2025; 31 (3): 27–45. https://doi.org/10.24835/1607-0771-322 (In Russian)

8. Goyal A., Hemachandran N., Kumar A. et al. Evaluation of the Graft Kidney in the Early Postoperative Period: Performance of Contrast-Enhanced Ultrasound and Additional Ultrasound Parameters. J. Ultrasound Med. 2021; 40 (9): 1771–1783. https://doi.org/10.1002/jum.15557

9. Zhang Z., Shao K., Zhou C. et al. Using 1/2 Descending Time in CEUS to Identify Renal Allograft Rejection. Acad. Radiol. 2024; 31 (8): 3248–3256. https://doi.org/10.1016/j.acra.2024.01.027

10. Friedl S., Jung E.M., Bergler T. et al. Factors influencing the time-intensity curve analysis of contrast-enhanced ultrasound in kidney transplanted patients: Toward a standardized contrast-enhanced ultrasound examination. Front. Med. (Lausanne). 2022; 9: 928567. https://doi.org/doi:10.3389/fmed.2022.928567

11. Macrì F., Di Pietro S., Liotta L. et al. Effects of size and location of regions of interest examined by use of contrast-enhanced ultrasonography on renal perfusion variables of dogs. Am. J. Vet. Res. 2016; 77 (8): 869–876. https://doi.org/10.2460/ajvr.77.8.869

12. Leinonen M.R., Raekallio M.R., Vainio O.M. et al. The effect of the sample size and location on contrast ultrasound measurement of perfusion parameters. Vet. Radiol. Ultrasound. 2011; 52 (1): 82–87.

13. Liu D.J.X., Hesta M., Stock E. et al. Renal perfusion parameters measured by contrast-enhanced ultrasound in healthy dogs demonstrate a wide range of variability in the long-term. Vet. Radiol. Ultrasound. 2019; 60 (2): 201–209. https://doi.org/10.1111/vru.12690

14. Almushayt S.J., Pham A., Phillips B.E. et al. Repeatability of Contrast-Enhanced Ultrasound to Determine Renal Cortical Perfusion. Diagnostics (Basel). 2022; 12 (5): 1293. https://doi.org/10.3390/diagnostics12051293


Review

For citations:


Larionova S.N., Belavina N.I., Vetsheva N.N., Balter R.B. Contrast-enhanced ultrasound examination of a stable functioning renal transplant. Pilot study. Medical Visualization. 2026;30(2):76-88. (In Russ.) https://doi.org/10.24835/1607-0763-1588

Views: 225

JATS XML


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1607-0763 (Print)
ISSN 2408-9516 (Online)