Prospects for the use of right ventricular cavity modeling in children with pulmonary artery valve atresia and intact interventricular septum according to CTА
https://doi.org/10.24835/1607-0763-1603
Abstract
Purpose. The purpose of this study is to compare the values obtained from echocardiography (echoCG) and computed tomography angiography (CTA) for measuring the end-diastolic volume (EDV) of the right ventricle (RV) and its ejection fraction (EF). This comparison will be done using 3D modeling of the heart chambers.
Materials and Methods. A retrospective analysis of CTA and echoCG data will be performed on 12 patients diagnosed with pulmonary artery atresia and an intact interventricular septum. These patients have been undergoing treatment from January 2014 to March 2025, and their data from various stages of correction for congenital heart disease will be included in the analysis.
Results. According to the results of 3D modeling based on CTA, the average end-diastolic volume of the right ventricle was 9.9 [2.7–12.9] ml, the end-systolic volume was 4.7 [1.7–6.6] ml, and the ejection fraction was 42 [18–70]%. When comparing the results of the 3D modeling with EchoCG data, there was a discrepancy in volumetric measurements and functional analysis. However, when comparing EDV of the right ventricle based on CTA with its linear measurements based on EchoCG, a strong correlation was found, with r = 0.86 for end-diastolic size in the basal region, r = 0.84 in the middle region, and r = 0.80 along the long axis. Additionally, when comparing the ejection fraction calculated from CT data with the fraction of change in area of the right ventricle, a moderate positive correlation of r = 0.31 was observed.
Conclusion. The use of 3D modeling and 3D printing for children with pulmonary artery atresia and intact interventricular septum allows for personalized planning of surgical interventions on the heart, enabling a more accurate analysis of the anatomical features of the defect and more precise assessment of end-diastolic volumes and ventricular ejection fractions during patient follow-up.
About the Authors
E. KobelevRussian Federation
Eugenii Kobelev – Cand. of Sci. (Med.), junior researcher, Scientific Research Department of Radiation and Instrumental Diagnostics, E.N. Meshalkin National Research Medical Center, Novosibirsk
https://orcid.org/0000-0002-5901-2271
A. V. Voitov
Russian Federation
Alexey V. Voitov – Cand. of Sci. (Med.),, senior researcher, Scientific Research Department of Congenital Heart Defects, Institute of Circulatory Pathology, E.N. Meshalkin National Research Medical Center, Novosibirsk
https://orcid.org/0000-0003-3797-4899
A. V. Fridman
Russian Federation
Alexander V. Fridman – radiologist at the X-ray Department, E.N. Meshalkin National Research Medical Center, Novosibirsk
https://orcid.org/0000-0002-2300-2418
I. A. Soinov
Russian Federation
Ilya A. Soinov – Doct. Sci. (Med.), Head of the Research Department of Congenital Heart Defects, Institute of Circulatory Pathology, E.N. Meshalkin National Research Medical Center, Novosibirsk
https://orcid.org/0000-0003-3691-2848
V. Yu. Usov
Russian Federation
Vladimir Yu. Usov – Doct. Sci. (Med.), Professor, Scientific Research Department of Radiation and Instrumental Diagnostics, E.N. Meshalkin National Research Medical Center, Novosibirsk
https://orcid.org/0000-0002-7352-6068
References
1. Kotov S.A., Sobolev A.V., Chvamania A.A., Butrim Yu.V. Transventricular balloon valvuloplasty of valvular pulmonary stenosis in newborn with type 1 pulmonary atresia with intact ventricular septum. Children's Heart and Vascular Diseases. 2019; 16 (4): 282–286. https://doi.org/10.24022/1810-0686-2019-16-4-282-286 (In Russian)
2. Gorla S.R., Thomas A., Singh A.P. Pulmonary Atresia With Intact Ventricular Septum. [Updated 2025 May 5]. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan-. Available from: https://www.ncbi.nlm.nih.gov/books/NBK546666/
3. Pickure Z., Kalinin A., Lejnieks A., Alekhin M.N. Current Echocardiographic
4. Techniques for Evaluation of the Right Ventricle. Kardiologiia. 2017; 57 (9): 54–64.
5. https://doi.org/10.18087/cardio.2017.9.10019 (In Russian)
6. Yaroshchuk N.A., Kochmasheva V.V., Dityatev V.P. Comparative analysis of left ventricular volume parameters by visualisation method in patients with myocardial infarction. Russian Journal of Cardiology. 2012; 5: 30–33. (In Russian)
7. Mah K., Mertens L. Echocardiographic Assessment of Right Ventricular Function in Paediatric Heart Disease: A Practical Clinical Approach. CJC Pediatr. Congenit. Heart Dis. 2022; 1 (3): 136–157. https://doi.org/10.1016/j.cjcpc.2022.05.002
8. Lopez L., Colan S.D., Frommelt P.C. et al. Recommendations for quantification methods during the performance of a pediatric echocardiogram: a report from the Pediatric Measurements Writing Group of the American Society of Echocardiography Pediatric and Congenital Heart Disease Council. J. Am. Soc. Echocardiogr. 2010; 23: 465–495. https://doi.org/10.1016/j.echo.2010.03.019
9. Rothstein E.S., Palac R.T., O’Rourke D.J. et al. Evaluation of echocardiographic derived parameters for right ventricular size and function using cardiac magnetic resonance imaging. Echocardiography. 2021; 38: 1336–1344. https://doi.org/10.1111/echo.15162
10. Lai W.W., Gauvreau K., Rivera E.S. et al. Accuracy of guideline recommendations for two-dimensional quantification of the right ventricle by echocardiography. Int. J. Cardiovasc. Imaging. 2008; 7: 691–698. https://doi.org/10.1007/s10554-008-9314-4
11. Yoshimura N., Yamaguchi M., Ohashi H. et al. Pulmonary atresia with intact ventricular septum: strategy based on right ventricular morphology. J. Thorac. Cardiovasc. Surg. 2003; 126 (5): 1417–1426. https://doi.org/10.1016/s0022-5223(03)01035-3
Review
For citations:
Kobelev E., Voitov A.V., Fridman A.V., Soinov I.A., Usov V.Yu. Prospects for the use of right ventricular cavity modeling in children with pulmonary artery valve atresia and intact interventricular septum according to CTА. Medical Visualization. 2026;30(2):20-25. (In Russ.) https://doi.org/10.24835/1607-0763-1603
JATS XML






























