<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">medvis</journal-id><journal-title-group><journal-title xml:lang="ru">Медицинская визуализация</journal-title><trans-title-group xml:lang="en"><trans-title>Medical Visualization</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1607-0763</issn><issn pub-type="epub">2408-9516</issn><publisher><publisher-name>RDS-Media Ltd.</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.24835/1607-0763-2020-3-107-113</article-id><article-id custom-type="elpub" pub-id-type="custom">medvis-954</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ГРУДНАЯ КЛЕТКА</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>THORAX</subject></subj-group></article-categories><title-group><article-title>Возможности применения модель-базированных итеративных реконструкций при компьютерной томографии легких</article-title><trans-title-group xml:lang="en"><trans-title>Possibilities of applying model-based iterative reconstructions in computed tomography of the lungs</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-4952-2347</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Силин</surname><given-names>А. Ю.</given-names></name><name name-style="western" xml:lang="en"><surname>Silin</surname><given-names>A. Yu.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Силин Антон Юрьевич – врач-рентгенолог высшей квалификационной категории, руководитель отделения лучевой диагностики; научный сотрудник</p><p>111033 Москва, Волочаевская ул., 15, к. 1, Российская Федерация;</p><p>125124 Москва, ул. Расковой, д. 16/26, стр. 1, Российская Федерация</p></bio><bio xml:lang="en"><p>Anton Yu. Silin – Radiologist of the Highest Qualification Category, Head of Radiology Department; Research and Practical Clinical Center of Diagnostics and Telemedicine Technologies</p><p>15-1, Volochaevskaya str., Moscow, 111033, Russian Federation;</p><p>16-26-1, Raskovoy str., Moscow, 125124, Russian Federation</p></bio><email xlink:type="simple">silin@yamed.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-0781-9898</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Груздев</surname><given-names>И. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Gruzdev</surname><given-names>I. S.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Груздев Иван Сергеевич – аспирант отделения рентгенологии и магнитно-резонансных методов исследования</p><p>117997 Москва, ул. Большая Серпуховская, д. 27, Российская Федерация</p></bio><bio xml:lang="en"><p>Ivan S. Gruzdev – graduate student of Radiology Department</p><p>27, Bol'shaya Serpukhovskaia str., Moscow, 117997, Russian Federation</p></bio><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-7077-7320</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Беркович</surname><given-names>Г. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Berkovich</surname><given-names>G. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Беркович Глеб Владимирович – заведующий кабинетом рентгеновской компьютерной томографии</p><p>197341 Санкт-Петербург, ул. Аккуратова, д. 2, Российская Федерация</p></bio><bio xml:lang="en"><p>Gleb V. Berkovich – Head of the CT office</p><p>2, Akkuratova str., St. Petersburg, 197341, Russian Federation</p></bio><xref ref-type="aff" rid="aff-3"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-5151-4579</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Николаев</surname><given-names>А. Е.</given-names></name><name name-style="western" xml:lang="en"><surname>Nikolaev</surname><given-names>A. E.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Николаев Александр Евгеньевич – младший научный сотрудник отдела развития качества радиологии</p><p>125124 Москва, ул. Расковой, д. 16/26, стр. 1, Российская Федерация</p></bio><bio xml:lang="en"><p>Aleksandr E. Nikolaev – junior researcher of Department of Radiology Quality Development</p><p>16-26-1, Raskovoy str., Moscow, 125124, Russian Federation</p></bio><xref ref-type="aff" rid="aff-4"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-6545-6170</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Морозов</surname><given-names>С. П.</given-names></name><name name-style="western" xml:lang="en"><surname>Morozov</surname><given-names>S. P.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Морозов Сергей Павлович – доктор медицинских наук, профессор, директор</p><p>125124 Москва, ул. Расковой, д. 16/26, стр. 1, Российская Федерация</p></bio><bio xml:lang="en"><p>Sergey P. Morozov – Medical doctor, Professor, Director</p><p>16-26-1, Raskovoy str., Moscow, 125124, Russian Federation</p></bio><xref ref-type="aff" rid="aff-4"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ООО “Клинический госпиталь на Яузе”; ГБУЗ “Научно-практический клинический центр диагностики и телемедицинских технологий Департамента здравоохранения города Москвы”</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Clinical hospital on Yauza; Research and Practical Clinical Center of Diagnostics and Telemedicine Technologies, Department of Health Care of Moscow</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>ФГБУ “НМИЦ хирургии имени А.В. Вишневского” Минздрава России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>A.V. Vishnevsky National Medical Research Center of Surgery</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-3"><aff xml:lang="ru"><institution>ФГБУ “НМИЦ имени В.А. Алмазова” Минздрава России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Almazov National Medical Research Centre</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-4"><aff xml:lang="ru"><institution>ГБУЗ “Научно-практический клинический центр диагностики и телемедицинских технологий Департамента здравоохранения города Москвы”</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Research and Practical Clinical Center of Diagnostics and Telemedicine Technologies, Department of Health Care of Moscow</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2020</year></pub-date><pub-date pub-type="epub"><day>09</day><month>10</month><year>2020</year></pub-date><volume>24</volume><issue>3</issue><fpage>107</fpage><lpage>113</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Силин А.Ю., Груздев И.С., Беркович Г.В., Николаев А.Е., Морозов С.П., 2020</copyright-statement><copyright-year>2020</copyright-year><copyright-holder xml:lang="ru">Силин А.Ю., Груздев И.С., Беркович Г.В., Николаев А.Е., Морозов С.П.</copyright-holder><copyright-holder xml:lang="en">Silin A.Y., Gruzdev I.S., Berkovich G.V., Nikolaev A.E., Morozov S.P.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://medvis.rdsmedia.ru/jour/article/view/954">https://medvis.rdsmedia.ru/jour/article/view/954</self-uri><abstract><sec><title>Цель исследования</title><p>Цель исследования: литературный обзор возможностей применения модельной итеративной реконструкции (МИР) при компьютерной томографии (КТ) для улучшения качества изображения, в том числе при низкодозовых протоколах сканирования.</p></sec><sec><title>Материал и методы</title><p>Материал и методы. Проведен анализ публикаций, посвященных применению МИР для снижения дозы облучения и улучшения качества изображений при КТ-диагностике патологии легких с акцентом на значение достигнутой дозы облучения.</p></sec><sec><title>Результаты</title><p>Результаты. Применение МИР позволяет устранять цифровой шум с медицинских изображений, улучшая их качество. Это свойство позволяет значительно снижать лучевую нагрузку при низкодозных протоколах без потери диагностического качества. В среднем использование МИР позволяет снизить дозу облучения на 70% по сравнению со стандартным протоколом, не повышая шумность КТ-изображений и сохраняя соотношение контраст/шум. Предыдущие исследования показали положительный опыт использования МИР в программах скрининга рака легкого и мониторинге онкологических пациентов.</p></sec><sec><title>Заключение</title><p>Заключение. Внедрение МИР в клиническую практику может оптимизировать лучевую нагрузку на популяцию, не снижая качество КТ-изображений, однако пороговые значения дозы облучения для достижения удовлетворительного качества изображения остаются неизученными.</p></sec></abstract><trans-abstract xml:lang="en"><sec><title>Aim</title><p>Aim: A literature review of the possibilities of applying model iterative reconstruction (MIR) in computed tomography to improve image quality, including in low-dose scanning protocols.</p></sec><sec><title>Materials and methods</title><p>Materials and methods. The analysis of publications devoted to the application of MIR to reduce the radiation dose and improve the quality of images in CT diagnostics of lung pathology with an emphasis on the value of the achieved radiation dose was carried out.</p></sec><sec><title>Results</title><p>Results. The use of MIR eliminates digital noise from medical images, improving their quality. This feature can significantly reduce radiation exposure with low-dose protocols without loss of diagnostic quality. On average, application of MIR allows to reduce the radiation dose by 70% compared to a standard protocol, without increasing the noise level of CT images and maintaining the contrast-to-noise ratio. Previous studies have shown positive experience with the use of MIR in lung cancer screening programs and monitoring of cancer patients.</p></sec><sec><title>Conclusion</title><p>Conclusion. The introduction of MIR in clinical practice can optimize the radiation exposure on the population without reducing the quality of CT images, however, the threshold dose to achieve a satisfactory image quality remains unexplored.</p></sec></trans-abstract><kwd-group xml:lang="ru"><kwd>модельная итеративная реконструкция</kwd><kwd>низкодозовая компьютерная томография</kwd><kwd>грудная клетка</kwd></kwd-group><kwd-group xml:lang="en"><kwd>model-based iterative reconstruction</kwd><kwd>low dose computed tomography</kwd><kwd>chest</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Mathews J.D., Forsythe A.V., Brady Z., Butler M.W., Goergen S.K., Byrnes G.B., Giles G.G., Wallace A.B., Anderson P.R., Guiver T.A., McGale P., Cain T.M., Dowty J.G., Bickerstaffe A.C., Darby S.C. Cancer risk in 680 000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians. Br. Med. J. 2013: f2360. https://doi.org/10.1136/bmj.f2360</mixed-citation><mixed-citation xml:lang="en">Mathews J.D., Forsythe A.V., Brady Z., Butler M.W., Goergen S.K., Byrnes G.B., Giles G.G., Wallace A.B., Anderson P.R., Guiver T.A., McGale P., Cain T.M., Dowty J.G., Bickerstaffe A.C., Darby S.C. Cancer risk in 680 000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians. Br. Med. J. 2013: f2360. https://doi.org/10.1136/bmj.f2360</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Padole A., Ali Khawaja R.D., Kalra M.K., Singh S. CT radiation dose and iterative reconstruction techniques. Am. J. Roentgenol. 2015; 204 (4): W384–W392. https://doi.org/10.2214/AJR.14.13241</mixed-citation><mixed-citation xml:lang="en">Padole A., Ali Khawaja R.D., Kalra M.K., Singh S. CT radiation dose and iterative reconstruction techniques. Am. J. Roentgenol. 2015; 204 (4): W384–W392. https://doi.org/10.2214/AJR.14.13241</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Mayo-Smith W.W., Hara A.K., Mahesh M., Sahani D.V., Pavlicek W. How I do it: managing radiation dose in CT. Radiology. 2014; 273 (3): 657–672. https://doi.org/10.1148/radiol.14132328</mixed-citation><mixed-citation xml:lang="en">Mayo-Smith W.W., Hara A.K., Mahesh M., Sahani D.V., Pavlicek W. How I do it: managing radiation dose in CT. Radiology. 2014; 273 (3): 657–672. https://doi.org/10.1148/radiol.14132328</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Aurumskjold M.L., Ydstrom K., Tingberg A., Soderberg M. Model-based iterative reconstruction enables the evaluation of thin-slice computed tomography images without degrading image quality or increasing radiation dose. Radiation Protection Dosimetry. 2016; 169 (1–4): 100–106. https://doi.org/10.1093/rpd/ncv474</mixed-citation><mixed-citation xml:lang="en">Aurumskjold M.L., Ydstrom K., Tingberg A., Soderberg M. Model-based iterative reconstruction enables the evaluation of thin-slice computed tomography images without degrading image quality or increasing radiation dose. Radiation Protection Dosimetry. 2016; 169 (1–4): 100–106. https://doi.org/10.1093/rpd/ncv474</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Morimoto L.N., Kamaya A., Boulay-Coletta I., Fleischmann D., Molvin L., Tian L., Fisher G., Wang J., Willmann J.K. Reduced dose CT with model-based iterative reconstruction compared to standard dose CT of the chest, abdomen, and pelvis in oncology patients: intra-individual comparison study on image quality and lesion conspicuity. Abdom. Radiol. 2017; 42 (9): 2279–2288. https://doi.org/10.1007/s00261-017-1140-5</mixed-citation><mixed-citation xml:lang="en">Morimoto L.N., Kamaya A., Boulay-Coletta I., Fleischmann D., Molvin L., Tian L., Fisher G., Wang J., Willmann J.K. Reduced dose CT with model-based iterative reconstruction compared to standard dose CT of the chest, abdomen, and pelvis in oncology patients: intra-individual comparison study on image quality and lesion conspicuity. Abdom. Radiol. 2017; 42 (9): 2279–</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Neroladaki A., Botsikas D., Boudabbous S., Becker C.D., Montet X. Computed tomography of the chest with modelbased iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations. Eur. Radiol. 2013; 23 (2): 360–366. https://doi.org/10.1007/s00330-012-2627-7</mixed-citation><mixed-citation xml:lang="en">https://doi.org/10.1007/s00261-017-1140-5</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Mehta D., Thompson R., Morton T., Dhanantwari A., Shefer E. Iterative model reconstruction: simultaneously lowered computed tomography radiation dose and improved image quality. Med. Phys. Int. J. 2013; 2 (1): 147–155.</mixed-citation><mixed-citation xml:lang="en">Neroladaki A., Botsikas D., Boudabbous S., Becker C.D., Montet X. Computed tomography of the chest with modelbased iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations. Eur. Radiol. 2013; 23 (2): 360–366. https://doi.org/10.1007/s00330-012-2627-7</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Беркович Г.В. Оценка параметров качества КТ-изображений, полученных с использованием различных поколений алгоритмов реконструкций. Лучевая диагностика и терапия. 2017; (3): 109–110.</mixed-citation><mixed-citation xml:lang="en">Mehta D., Thompson R., Morton T., Dhanantwari A., Shefer E. Iterative model reconstruction: simultaneously lowered computed tomography radiation dose and improved image quality. Med. Phys. Int. J. 2013; 2 (1): 147–155.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Padole A., Digumarthy S., Flores E., Madan R., Mishra S., Sharma A., Kalra M.K. Assessment of chest CT at CTDIvol less than 1 mGy with iterative reconstruction techniques. Br. J. Radiol. 2017; 90 (1071): 20160625. https://doi.org/10.1259/bjr.20160625</mixed-citation><mixed-citation xml:lang="en">Berkovich G.V. Estimating of CT image quality with different generations of image reconstructions. Luchevaya diagnostika i terapiya. 2017; 3: 109–110. (In Russian) 9. Padole A., Digumarthy S., Flores E., Madan R., Mishra S., Sharma A., Kalra M.K. Assessment of chest CT at CTDIvol less than 1 mGy with iterative reconstruction techniques. Br. J. Radiol. 2017; 90 (1071): 20160625. https://doi.org/10.1259/bjr.20160625</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Lee S.W., Kim Y., Shim S.S., Lee J.K., Lee S.J., Ryu Y.J., Chang J.H. Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction. Eur. Radiol. 2014; 24 (4): 817–826. https://doi.org/10.1007/s00330-013-3090-9</mixed-citation><mixed-citation xml:lang="en">Lee S.W., Kim Y., Shim S.S., Lee J.K., Lee S.J., Ryu Y.J., Chang J.H. Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction. Eur. Radiol. 2014; 24 (4): 817–826. https://doi.org/10.1007/s00330-013-3090-9</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Laqmani A., Avanesov M., Butscheidt S., Kurfurst M., Sehner S., Schmidt-Holtz J., Derlin T., Behzadi C., Nagel H.D., Adam G., Regier M. Comparison of image quality and visibility of normal and abnormal findings at submillisievert chest CT using filtered back projection, iterative model reconstruction (IMR) and iDose4™. Eur. J. Radiol. 2016; 85 (11): 1971–1979. https://doi.org/10.1016/j.ejrad.2016.09.001</mixed-citation><mixed-citation xml:lang="en">Laqmani A., Avanesov M., Butscheidt S., Kurfurst M., Sehner S., Schmidt-Holtz J., Derlin T., Behzadi C., Nagel H.D., Adam G., Regier M. Comparison of image quality and visibility of normal and abnormal findings at submillisievert chest CT using filtered back projection, iterative model reconstruction (IMR) and iDose4™. Eur. J. Radiol. 2016; 85 (11): 1971–1979. https://doi.org/10.1016/j.ejrad.2016.09.001</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Ju Y.H., Lee G., Lee J.W., Hong S.B., Suh Y.J., Jeong Y.J. Ultra-low-dose lung screening CT with model-based iterative reconstruction: an assessment of image quality and lesion conspicuity. Acta Radiol. 2018; 59 (5): 553–559. https://doi.org/10.1177%2F0284185117726099</mixed-citation><mixed-citation xml:lang="en">Ju Y.H., Lee G., Lee J.W., Hong S.B., Suh Y.J., Jeong Y.J. Ultra-low-dose lung screening CT with model-based iterative reconstruction: an assessment of image quality and lesion conspicuity. Acta Radiol. 2018; 59 (5): 553–559. https://doi.org/10.1177%2F0284185117726099</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Baumueller S., Winklehner A., Karlo C., Goetti R., Flohr T., Russi E.W., Frauenfelder T., Alkadhi H. Low-dose CT of the lung: potential value of iterative reconstructions. Eur. Radiol. 2012; 22 (12): 2597–2606. https://doi.org/10.1007/s00330-012-2524-0</mixed-citation><mixed-citation xml:lang="en">Baumueller S., Winklehner A., Karlo C., Goetti R., Flohr T., Russi E.W., Frauenfelder T., Alkadhi H. Low-dose CT of the lung: potential value of iterative reconstructions. Eur. Radiol. 2012; 22 (12): 2597–2606. https://doi.org/10.1007/s00330-012-2524-0</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Kim Y., Kim Y.K., Lee B.E., Lee S.J., Ryu Y.J., Lee J.H., Chang J.H. Ultra-low-dose CT of the thorax using iterative reconstruction: evaluation of image quality and radiation dose reduction. Am. J. Roentgenol. 2015; 204 (6): 1197–1202. https://doi.org/10.2214/AJR.14.13629</mixed-citation><mixed-citation xml:lang="en">Kim Y., Kim Y.K., Lee B.E., Lee S.J., Ryu Y.J., Lee J.H., Chang J.H. Ultra-low-dose CT of the thorax using iterative reconstruction: evaluation of image quality and radiation dose reduction. Am. J. Roentgenol. 2015; 204 (6): 1197–1202. https://doi.org/10.2214/AJR.14.13629</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Hammond E., Sloan C., Newell J.D. Jr., Sieren J.P., Saylor M., Vidal C., Hogue S., de Stefano F., Sieren A., Hoffman E.A., Sieren J.C. Comparison of low- and ultralow- dose computed tomography protocols for quantitative lung and airway assessment. Med. Phys. 2017; 44 (9): 4747–4757. https://doi.org/10.1002/mp.12436</mixed-citation><mixed-citation xml:lang="en">Hammond E., Sloan C., Newell J.D. Jr., Sieren J.P., Saylor M., Vidal C., Hogue S., de Stefano F., Sieren A., Hoffman E.A., Sieren J.C. Comparison of low- and ultralow- dose computed tomography protocols for quantitative lung and airway assessment. Med. Phys. 2017; 44 (9): 4747–4757. https://doi.org/10.1002/mp.12436</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Hata A., Yanagawa M., Kikuchi N., Honda O., Tomiyama N. Pulmonary Emphysema Quantification on Ultra-Low-Dose Computed Tomography Using Model-Based Iterative Reconstruction With or Without Lung Setting. J. Comput. Assist. Tomogr. 2018; 42 (5): 760–766. https://10.1097/RCT.0000000000000755</mixed-citation><mixed-citation xml:lang="en">Hata A., Yanagawa M., Kikuchi N., Honda O., Tomiyama N. Pulmonary Emphysema Quantification on Ultra-Low-Dose Computed Tomography Using Model-Based Iterative Reconstruction With or Without Lung Setting. J. Comput. Assist. Tomogr. 2018; 42 (5): 760–766. https://10.1097/RCT.0000000000000755</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Jia Y., Ji X., He T., Yu Y., Yu N., Duan H., Guo Y. Quantitative Analysis of Airway Tree in Low-dose Chest CT with a New Model-based Iterative Reconstruction Algorithm: Comparison to Adaptive Statistical Iterative Reconstruction in Routine-dose CT. Acad. Radiol. 2018; 25 (12): 1526–1532. https://doi.org/10.1016/j.acra.2018.03.021</mixed-citation><mixed-citation xml:lang="en">Jia Y., Ji X., He T., Yu Y., Yu N., Duan H., Guo Y. Quantitative Analysis of Airway Tree in Low-dose Chest CT with a New Model-based Iterative Reconstruction Algorithm: Comparison to Adaptive Statistical Iterative Reconstruction in Routine-dose CT. Acad. Radiol. 2018; 25 (12): 1526–1532. https://doi.org/10.1016/j.acra.2018.03.021</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Kim C., Lee K.Y., Shin C., Kang E.Y., Oh Y.W., Ha M., Ko C.S., Cha, J. Comparison of filtered back projection, hybrid iterative reconstruction, model-based iterative reconstruction, and virtual monoenergetic reconstruction images at both low-and standard-dose settings in measurement of emphysema volume and airway wall thickness: a CT phantom study. Korean J. Radiol. 2018; 19 (4): 809–817. https://doi.org/10.3348/kjr.2018.19.4.809</mixed-citation><mixed-citation xml:lang="en">Kim C., Lee K.Y., Shin C., Kang E.Y., Oh Y.W., Ha M., Ko C.S., Cha, J. Comparison of filtered back projection, hybrid iterative reconstruction, model-based iterative reconstruction, and virtual monoenergetic reconstruction images at both low-and standard-dose settings in measurement of emphysema volume and airway wall thickness: a CT phantom study. Korean J. Radiol. 2018; 19 (4): 809–817. https://doi.org/10.3348/kjr.2018.19.4.809</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Gomez-Cardona D., Nagle S.K., Li K., Robinson T.E., Chen G.H. Influence of radiation dose and reconstruction algorithm in MDCT assessment of airway wall thickness: A phantom study. Med. Phys. 2015; 42 (10): 5919–5927. https://doi.org/10.1118/1.4930797</mixed-citation><mixed-citation xml:lang="en">Gomez-Cardona D., Nagle S.K., Li K., Robinson T.E., Chen G.H. Influence of radiation dose and reconstruction algorithm in MDCT assessment of airway wall thickness: A phantom study. Med. Phys. 2015; 42 (10): 5919–5927. https://doi.org/10.1118/1.4930797</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Hammond E., Chan K.S., Ames J.C., Stoyles N., Sloan C.M., Guo J., Newell J.D. Jr., Sieren J.C. Impact of advanced detector technology and iterative reconstruction on low-dose quantitative assessment of lung computed tomography density in a biological lung model. Med. Phys. 2018; 45(8): 3657–3670. https://doi.org/10.1002/mp.13057</mixed-citation><mixed-citation xml:lang="en">Hammond E., Chan K.S., Ames J.C., Stoyles N., Sloan C.M., Guo J., Newell J.D. Jr., Sieren J.C. Impact of advanced detector technology and iterative reconstruction on low-dose quantitative assessment of lung computed tomography density in a biological lung model. Med. Phys. 2018; 45(8): 3657–3670. https://doi.org/10.1002/mp.13057</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Katsura M., Sato J., Akahane M., Mise Y., Sumida K., Abe O. Effects of pure and hybrid iterative reconstruction algorithms on high-resolution computed tomography in the evaluation of interstitial lung disease. Eur. J. Radiol. 2017; 93: 243–251. https://doi.org/10.1016/j.ejrad.2017.06.003</mixed-citation><mixed-citation xml:lang="en">Katsura M., Sato J., Akahane M., Mise Y., Sumida K., Abe O. Effects of pure and hybrid iterative reconstruction algorithms on high-resolution computed tomography in the evaluation of interstitial lung disease. Eur. J. Radiol. 2017; 93: 243–251. https://doi.org/10.1016/j.ejrad.2017.06.003</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">de Margerie-Mellon C., de Bazelaire C., Montlahuc C., Lambert J., Martineau A., Coulon P., de Kerviler E., Beigelman C. Reducing radiation dose at chest CT: comparison among model-based type iterative reconstruction, hybrid iterative reconstruction, and filtered back projection. Acad. Radiol. 2016; 23(10): 1246–1254. https://doi.org/10.1016/j.acra.2016.05.019</mixed-citation><mixed-citation xml:lang="en">de Margerie-Mellon C., de Bazelaire C., Montlahuc C., Lambert J., Martineau A., Coulon P., de Kerviler E., Beigelman C. Reducing radiation dose at chest CT: comparison among model-based type iterative reconstruction, hybrid iterative reconstruction, and filtered back projection. Acad. Radiol. 2016; 23(10): 1246–1254. https://doi.org/10.1016/j.acra.2016.05.019</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Xin X., Shen J., Yang S., Liu S., Hu A., Zhu B., Jiang Y., Li B., Zhang B. Improved image quality of low-dose CT combining with iterative model reconstruction algorithm for response assessment in patients after treatment of malignant tumor. Quant. Imaging Med. Surg. 2018; 8 (7): 648. https://dx.doi.org/10.21037%2Fqims.2018.08.05</mixed-citation><mixed-citation xml:lang="en">Xin X., Shen J., Yang S., Liu S., Hu A., Zhu B., Jiang Y., Li B., Zhang B. Improved image quality of low-dose CT combining with iterative model reconstruction algorithm for response assessment in patients after treatment of malignant tumor. Quant. Imaging Med. Surg. 2018; 8 (7): 648. https://dx.doi.org/10.21037%2Fqims.2018.08.05</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
