<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">medvis</journal-id><journal-title-group><journal-title xml:lang="ru">Медицинская визуализация</journal-title><trans-title-group xml:lang="en"><trans-title>Medical Visualization</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1607-0763</issn><issn pub-type="epub">2408-9516</issn><publisher><publisher-name>RDS-Media Ltd.</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.24835/1607-0763-2018-1-26-35</article-id><article-id custom-type="elpub" pub-id-type="custom">medvis-504</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ГРУДНАЯ КЛЕТКА</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>THORAX</subject></subj-group></article-categories><title-group><article-title>МЕТОДОЛОГИЧЕСКИЕ АСПЕКТЫ ВИЗУАЛИЗАЦИИ КОРОНАРНЫХ АРТЕРИЙ ПРИ ТРАНСТОРАКАЛЬНОЙ ЭХОКАРДИОГРАФИИ</article-title><trans-title-group xml:lang="en"><trans-title>METHODOLOGICAL ASPECTS OF VISUALIZATION OF CORONARY ARTERIES WITH TRANSTHORACIC ECHOCARDIOGRAPHY</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Агаева</surname><given-names>З. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Agaeva</surname><given-names>Z. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Агаева Зоя Абуевна – доктор медицинских наук, профессор кафедры лучевой диагностики, лучевой терапии.</p><p>Краснодар</p></bio><bio xml:lang="en"><p>Zoya A. Agaeva – doct. of med. sci., professor of chair of radiology methods of diagnostics and treatment.</p><p>Krasnodar</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Багдасарян</surname><given-names>К. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Baghdasaryan</surname><given-names>K. B.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Багдасарян Карапет Акопович – аспирант кафедры лучевой диагностики, лучевой терапии.</p><p>350063 Краснодар, ул. Седина, 4, 8-961-507-97-44</p></bio><bio xml:lang="en"><p>Karapet A. Baghdasaryan – postgraduate (aspirant) of chair of radiology methods of diagnostics and treatment.</p><p>350063 Krasnodar, Sedina str., 4, 8-961-507-97-44</p></bio><email xlink:type="simple">kbagdasaryan.83@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГБОУ ВО “Кубанский государственный медицинский университет” Минздрава России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Kuban State Medical University</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2018</year></pub-date><pub-date pub-type="epub"><day>28</day><month>02</month><year>2018</year></pub-date><volume>0</volume><issue>1</issue><fpage>26</fpage><lpage>35</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Агаева З.А., Багдасарян К.А., 2018</copyright-statement><copyright-year>2018</copyright-year><copyright-holder xml:lang="ru">Агаева З.А., Багдасарян К.А.</copyright-holder><copyright-holder xml:lang="en">Agaeva Z.A., Baghdasaryan K.B.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://medvis.rdsmedia.ru/jour/article/view/504">https://medvis.rdsmedia.ru/jour/article/view/504</self-uri><abstract><p>Трансторакальная эхокардиография, выполненная с помощью мультичастотных датчиков с поддержкой режима второй тканевой гармоники, является конкурентоспособным методом для визуализации магистральных коронарных артерий и позволяет качественно оценить спектр коронарного кровотока в них. Безусловно, у метода есть значительные ограничения, самой главной из которых является низкая пространственная разрешающая способность метода из-за небольшого акустического окна. Именно из-за этого трансторакальное исследование коронарных артерий, по всей видимости, не станет лидирующим методом анатомической реконструкции отдельно взятой коронарной артерии и тем более всего коронарного русла. Однако уникальностью и неоспоримым преимуществом данного метода является  возможность неинвазивно оценить коронарный кровоток как однократно, так и в динамике.</p></abstract><trans-abstract xml:lang="en"><p>The transthoracic echocardiography made by multifrequency probes with support of the mode of the second harmonic imaging, is a competitive method for visualization of the main coronary arteries and allows to estimate coronary blood flow with high quality. Of course, the method has considerable restrictions, most important of which is the low spatial resolution of a method, due to small acoustic window. Because of this the transthoracic visualization of coronary arteries perhaps will not become the leading method of anatomic reconstruction of separately taken coronary artery and especially all coronary arteries system. However uniqueness and indisputable advantage of this method is an opportunity to noninvasively estimate a coronary blood flow both once, and in dynamics.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>трансторакальная эхокардиография</kwd><kwd>допплерография</kwd><kwd>магистральные коронарные артерии</kwd></kwd-group><kwd-group xml:lang="en"><kwd>transthoracic echocardiography</kwd><kwd>Doppler</kwd><kwd>main coronary arteries</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Ross J.J., Mintz G.S., Chandrasekaran K. Transthoracic two-dimensional high frequency (7.5 MHz) ultrasonic visualization of the distal left anterior descending coronary artery. J. Am. Coll. Cardiol. 1990; 15: 373–377.</mixed-citation><mixed-citation xml:lang="en">Ross J.J., Mintz G.S., Chandrasekaran K. Transthoracic two-dimensional high frequency (7.5 MHz) ultrasonic visualization of the distal left anterior descending coronary artery. J. Am. Coll. Cardiol. 1990; 15: 373–377.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Kenny A., Shapiro L.M. Transthoracic high-frequency twodimensional echocardiography, Doppler and color flow mapping to determine anatomy and blood flow patterns in the distal left anterior descending coronary artery. Am. J. Cardiol. 1992; 69 (16): 1265–1268.</mixed-citation><mixed-citation xml:lang="en">Kenny A., Shapiro L.M. Transthoracic high-frequency twodimensional echocardiography, Doppler and color flow mapping to determine anatomy and blood flow patterns in the distal left anterior descending coronary artery. Am. J. Cardiol. 1992; 69 (16): 1265–1268.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Kiviniemi T.O., Saraste M., Koskenvuo J.W., Airaksinen K.E., Toikka J.O., Saraste A., Parkka J.P., Hartiala J.J. Coronary artery diameter can be assessed reliably with transthoracic echocardiography. Am. J. Physiol. Heart Circ. Physiol. 2004; 286: H1515–H1520.</mixed-citation><mixed-citation xml:lang="en">Kiviniemi T.O., Saraste M., Koskenvuo J.W., Airaksinen K.E., Toikka J.O., Saraste A., Parkka J.P., Hartiala J.J. Coronary artery diameter can be assessed reliably with transthoracic echocardiography. Am. J. Physiol. Heart Circ. Physiol. 2004; 286: H1515–H1520.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Harada K., Orino T., Hironaka C., Takahashi Y., Takada G. Coronary blood flow velocity in normal infants and youngadults assessed by transthoracic echocardiography. Am. J. Cardiol. 1999; 83 (11): 1583–1585.</mixed-citation><mixed-citation xml:lang="en">Harada K., Orino T., Hironaka C., Takahashi Y., Takada G. Coronary blood flow velocity in normal infants and young adults assessed by transthoracic echocardiography. Am. J. Cardiol. 1999; 83 (11): 1583–1585.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Hiraishi S., Misawa H., Takeda N., Horiguchi Y., Fujino N., Ogawa N., Hirota H. Transthoracic ultrasonic visualization of coronary aneurysm, stenosis, and occlusion in Kawasaki disease. Heart. 2000; 83 (4): 400–405.</mixed-citation><mixed-citation xml:lang="en">Hiraishi S., Misawa H., Takeda N., Horiguchi Y., Fujino N., Ogawa N., Hirota H. Transthoracic ultrasonic visualization of coronary aneurysm, stenosis, and occlusion in Kawasaki disease. Heart. 2000; 83 (4): 400–405.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Hiraishi S., Hirota H., Horiguchi Y., Takeda N., Fujino N., Ogawa N., Nakahata Y. Transthoracic doppler assessment of coronary flow velocity reserve in children with Kawasaki disease: comparison with coronary angiography and thallium-201 imaging. J. Am. Coll. Cardiol. 2002; 40: 1816–1824.</mixed-citation><mixed-citation xml:lang="en">Hiraishi S., Hirota H., Horiguchi Y., Takeda N., Fujino N., Ogawa N., Nakahata Y. Transthoracic doppler assessment of coronary flow velocity reserve in children with Kawasaki disease: comparison with coronary angiography and thallium-201 imaging. J. Am. Coll. Cardiol. 2002; 40: 1816–1824.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Frommelt P.C., Frommelt M.A. Congenital coronary artery anomalies. Pediatr. Clin. N. Am. 2004; 51 (5): 1273–1278.</mixed-citation><mixed-citation xml:lang="en">Frommelt P.C., Frommelt M.A. Congenital coronary artery anomalies. Pediatr. Clin. N. Am. 2004; 51 (5): 1273–1278.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Youn H.J., Foster E. Demonstration of coronary artery flow using transthoracic doppler echocardiography. J. Am. Soc. Echocardiogr. 2004; 17: 178–185.</mixed-citation><mixed-citation xml:lang="en">Youn H.J., Foster E. Demonstration of coronary artery flow using transthoracic doppler echocardiography. J. Am. Soc. Echocardiogr. 2004; 17: 178–185.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Isaaz K., Da Costa A., De Pasquale J.P., Cerisier A., Lamaud M. Use of the continuity equation for transesophageal Doppler assessment of severity of proximal left coronary artery stenosis: a quantitative coronary angiography validation study. J. Am. Coll. Cardiol. 1998; 32: 42–48.</mixed-citation><mixed-citation xml:lang="en">Isaaz K., Da Costa A., De Pasquale J.P., Cerisier A., Lamaud M. Use of the continuity equation for transesophageal Doppler assessment of severity of proximal left coronary artery stenosis: a quantitative coronary angiography validation study. J. Am. Coll. Cardiol. 1998; 32: 42–48.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Youn H.J., Foster E. Transesophageal echocardiography (TEE) in the evaluation of the coronary arteries. Cardiol. Clin. 2000; 18 (4): 833–848.</mixed-citation><mixed-citation xml:lang="en">Youn H.J., Foster E. Transesophageal echocardiography (TEE) in the evaluation of the coronary arteries. Cardiol. Clin. 2000; 18 (4): 833–848.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Paraskevaidis I.A., Tsiapras D., Karavolias G.K., Kyriakides Z.S., Kremastinos D.Th. Serial evaluation of coronary flow reserve by transesophageal Doppler echocardiography after angioplasty of proximal left anterior descending coronary artery: a 6-month follow-up study. Coron. Artery Dis. 2001; 12: 45–52.</mixed-citation><mixed-citation xml:lang="en">Paraskevaidis I.A., Tsiapras D., Karavolias G.K., Kyriakides Z.S., Kremastinos D.Th. Serial evaluation of coronary flow reserve by transesophageal Doppler echocardiography after angioplasty of proximal left anterior descending coronary artery: a 6-month follow-up study. Coron. Artery Dis. 2001; 12: 45–52.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Vrublevsky A.V., Boshchenko A.A., Karpov R.S. Simultaneous transesophageal Doppler assessment of coronary flow reserve in the left anterior descending artery and coronary sinus allows differentiation between proximal and non-proximal left anterior descending artery stenoses. Eur. J. Echocardiogr. 2004; 5 (1): 25–33.</mixed-citation><mixed-citation xml:lang="en">Vrublevsky A.V., Boshchenko A.A., Karpov R.S. Simultaneous transesophageal Doppler assessment of coronary flow reserve in the left anterior descending artery and coronary sinus allows differentiation between proximal and non-proximal left anterior descending artery stenoses. Eur. J. Echocardiogr. 2004; 5 (1): 25–33.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Kasprzak J.D., Drozdz J., Peruga J.Z., Rafalska K., Krzeminska-Pakula M. Definition of normal flow parameters in proximal coronary arteries using transesophageal Doppler echocardiography. Echocardiography. 2000; 17: 141–150.</mixed-citation><mixed-citation xml:lang="en">Kasprzak J.D., Drozdz J., Peruga J.Z., Rafalska K., Krzeminska-Pakula M. Definition of normal flow parameters in proximal coronary arteries using transesophageal Doppler echocardiography. Echocardiography. 2000; 17: 141–150.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Vrublevsky A.V., Boshchenko A.A., Karpov R.S. Diagnostics of main coronary artery stenosis and occlusions: multiplane transoesophageal Doppler echocardiographic assessment. Eur. J. Echocardiogr. 2001; 2 (3): 170–177.</mixed-citation><mixed-citation xml:lang="en">Vrublevsky A.V., Boshchenko A.A., Karpov R.S. Diagnostics of main coronary artery stenosis and occlusions: multiplane transoesophageal Doppler echocardiographic assessment. Eur. J. Echocardiogr. 2001; 2 (3): 170–177.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Hirata N., Asaoka N., Hatsuoka S., Kosakai Y. Noninvasive evaluation of internal thoracic artery and left anterior descending coronary artery anatomic sites using transthoracic Doppler echocardiography: comparison with coronary arteriography. J. Thorac. Cardiovasc. Surg. 2003; 126 (4): 1080–1086.</mixed-citation><mixed-citation xml:lang="en">Hirata N., Asaoka N., Hatsuoka S., Kosakai Y. Noninvasive evaluation of internal thoracic artery and left anterior descending coronary artery anatomic sites using transthoracic Doppler echocardiography: comparison with coronary arteriography. J. Thorac. Cardiovasc. Surg. 2003; 126 (4): 1080–1086.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Pellikka P. Going for the money: transthoracic assessment of coronary artery flow reserve. J. Am. Soc. Echocardiogr. 2004; 17 (6): 700–703.</mixed-citation><mixed-citation xml:lang="en">Pellikka P. Going for the money: transthoracic assessment of coronary artery flow reserve. J. Am. Soc. Echocardiogr. 2004; 17 (6): 700–703.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">West A.M., Kramer C.M. Noninvasive imaging of the heart and coronary arteries. Surg. Clin. N. Am. 2009; 89: 763– 780.</mixed-citation><mixed-citation xml:lang="en">West A.M., Kramer C.M. Noninvasive imaging of the heart and coronary arteries. Surg. Clin. N. Am. 2009; 89: 763– 780.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Crowley J.J., Shapiro L.M. Noninvasive analysis of coronary artery poststenotic flow characteristics by using transthoracic echocardiography. J. Am. Soc. Echocardiogr. 1998; 11 (1): 1–9.</mixed-citation><mixed-citation xml:lang="en">Crowley J.J., Shapiro L.M. Noninvasive analysis of coronary artery poststenotic flow characteristics by using transthoracic echocardiography. J. Am. Soc. Echocardiogr. 1998; 11 (1): 1–9.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Krzanowski M., Bodzon W., Brzostek T., Nizankowski R., Szczeklik A. Value of transthoracic echocardiography for the detection of high-grade coronary artery stenosis: prospective evaluation in 50 consecutive patients scheduled for coronary angiography. J. Am. Soc. Echocardiogr. 2000; 13: 1091–1099.</mixed-citation><mixed-citation xml:lang="en">Krzanowski M., Bodzon W., Brzostek T., Nizankowski R., Szczeklik A. Value of transthoracic echocardiography for the detection of high-grade coronary artery stenosis: prospective evaluation in 50 consecutive patients scheduled for coronary angiography. J. Am. Soc. Echocardiogr. 2000; 13: 1091–1099.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Higashiue S., Watanabe H., Yokoi Y., Takeuchi K., Yoshikawa J. Simple detection of severe coronary stenosis using transthoracic Doppler echocardiography at rest. Am. J. Cardiol. 2001; 87: 1064–1068.</mixed-citation><mixed-citation xml:lang="en">Higashiue S., Watanabe H., Yokoi Y., Takeuchi K., Yoshikawa J. Simple detection of severe coronary stenosis using transthoracic Doppler echocardiography at rest. Am. J. Cardiol. 2001; 87: 1064–1068.</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Lethen H., Tries H.P., Brechtken J., Kersting S., Lambertz H. Comparison of transthoracic Doppler echocardiography to intracoronary Doppler guide-wire measurements for assessment of coronary flow reserve in the left anterior descending artery for detection of restenosis after coronary angioplasty. Am. J. Cardiol. 2003; 91 (4): 412–417.</mixed-citation><mixed-citation xml:lang="en">Lethen H., Tries H.P., Brechtken J., Kersting S., Lambertz H. Comparison of transthoracic Doppler echocardiography to intracoronary Doppler guide-wire measurements for assessment of coronary flow reserve in the left anterior descending artery for detection of restenosis after coronary angioplasty. Am. J. Cardiol. 2003; 91 (4): 412–417.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Daimon M., Watanabe H., Yamagishi H., Kuwabara Y., Hasegawa R., Toyoda T., Yoshida K., Yoshikawa J., Komuro I. Physiologic assessment of coronary artery stenosis without stress tests: noninvasive analysis of phasic flow characteristics by transthoracic Doppler echocardiography. J. Am. Soc. Echocardiogr. 2005; 18 (9): 949–955.</mixed-citation><mixed-citation xml:lang="en">Daimon M., Watanabe H., Yamagishi H., Kuwabara Y., Hasegawa R., Toyoda T., Yoshida K., Yoshikawa J., Komuro I. Physiologic assessment of coronary artery stenosis without stress tests: noninvasive analysis of phasic flow characteristics by transthoracic Doppler echocardiography. J. Am. Soc. Echocardiogr. 2005; 18 (9): 949–955.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Vegsundvåg J., Holte E., Wiseth R., Hegbom K., Hole T. Transthoracic echocardiography for imaging of the different coronary artery segments: a feasibility study [Electronic resource]. Cardiovasc. Ultrasound. 2009; 7. URL: http://www.cardiovascularultrasound.com/content/7/1/58. (22 December 2009). http://www.cardiovascularultrasound.com/content/1/1/16. (дата обращения 1.10.2017).</mixed-citation><mixed-citation xml:lang="en">Vegsundvåg J., Holte E., Wiseth R., Hegbom K., Hole T. Transthoracic echocardiography for imaging of the different coronary artery segments: a feasibility study [Electronic resource]. Cardiovasc. Ultrasound. 2009; 7. URL: http://www.cardiovascularultrasound.com/ content/7/1/58. (22 December 2009). http://www.cardiovascularultrasound.com/content/1/1/16. (дата обращения 1.10.2017).</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Vegsundvåg J., Holte E., Wiseth R., Hegbom K., Hole T. Coronary flow velocity reserve in the three main coronary arteries assessed with transthoracic Doppler: a comparative study with quantitative coronary angiography. J. Am. Soc. Echocardiogr. 2011; 24 (7): 758–767. DOI: 10.1016/j.echo.2011.03.010</mixed-citation><mixed-citation xml:lang="en">Vegsundvåg J., Holte E., Wiseth R., Hegbom K., Hole T. Coronary flow velocity reserve in the three main coronary arteries assessed with transthoracic Doppler: a comparative study with quantitative coronary angiography. J. Am. Soc. Echocardiogr. 2011; 24 (7): 758–767.  DOI: 10.1016/j.echo.2011.03.010</mixed-citation></citation-alternatives></ref><ref id="cit25"><label>25</label><citation-alternatives><mixed-citation xml:lang="ru">Watanabe N., Akasaka T., Yamaura Y., Akiyama M., Koyama Y., Kamiyama N., Neishi Y., Kaji S., Saito Y., Yoshida K. Noninvasive detection of total occlusion of the left anterior descending coronary artery with transthoracic Doppler echocardiography. J. Am. Coll. Cardiol. 2001; 38: 1328–1332.</mixed-citation><mixed-citation xml:lang="en">Watanabe N., Akasaka T., Yamaura Y., Akiyama M., Koyama Y., Kamiyama N., Neishi Y., Kaji S., Saito Y., Yoshida K. Noninvasive detection of total occlusion of the left anterior descending coronary artery with transthoracic Doppler echocardiography. J. Am. Coll. Cardiol. 2001; 38: 1328–1332.</mixed-citation></citation-alternatives></ref><ref id="cit26"><label>26</label><citation-alternatives><mixed-citation xml:lang="ru">Voci P., Pizzuto F., Mariano E., Puddu P.E., Chiavari P.A., Romeo F. Measurement of coronary flow reserve in the anterior and posterior descending coronary arteries by transthoracic Doppler ultrasound. Am. J. Cardiol. 2002; 90: 988–991.</mixed-citation><mixed-citation xml:lang="en">Voci P., Pizzuto F., Mariano E., Puddu P.E., Chiavari P.A., Romeo F. Measurement of coronary flow reserve in the anterior and posterior descending coronary arteries by transthoracic Doppler ultrasound. Am. J. Cardiol. 2002; 90: 988–991.</mixed-citation></citation-alternatives></ref><ref id="cit27"><label>27</label><citation-alternatives><mixed-citation xml:lang="ru">Fujimoto K., Watanabe H., Hozumi T., Otsuka R., Hirata K., Yamagishi H., Yoshiyama M., Yoshikawa J. New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography: comparison with thallium-201 single photon emission computed tomography. J. Cardiol. 2004; 43 (3): 109–116.</mixed-citation><mixed-citation xml:lang="en">Fujimoto K., Watanabe H., Hozumi T., Otsuka R., Hirata K., Yamagishi H., Yoshiyama M., Yoshikawa J. New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography: comparison with thallium-201 single photon emission computed tomography. J. Cardiol. 2004; 43 (3): 109–116.</mixed-citation></citation-alternatives></ref><ref id="cit28"><label>28</label><citation-alternatives><mixed-citation xml:lang="ru">Saraste M., Vesalainen R.K., Ylitalo A., Saraste A., Koskenvuo J.W., Toikka J.O., Vaittinen M.A., Hartiala J.J., Airaksinen K.E. Transthoracic Doppler echocardiography as a noninvasive tool to assess coronary artery stenoses – a comparison with quantitative coronary angiography. J. Am. Soc. Echocardiogr. 2005; 18 (6): 679–685.</mixed-citation><mixed-citation xml:lang="en">Saraste M., Vesalainen R.K., Ylitalo A., Saraste A., Koskenvuo J.W., Toikka J.O., Vaittinen M.A., Hartiala J.J., Airaksinen K.E. Transthoracic Doppler echocardiography as a noninvasive tool to assess coronary artery stenoses – a comparison with quantitative coronary angiography. J. Am. Soc. Echocardiogr. 2005; 18 (6): 679–685.</mixed-citation></citation-alternatives></ref><ref id="cit29"><label>29</label><citation-alternatives><mixed-citation xml:lang="ru">Caiati C., Zedda N., Cadeddu M., Chen L., Montaldo C., Iliceto S., Lepera M.E., Favale S. Detection, location, and severity assessment of left anterior descending coronary artery stenoses by means of contrast-enhanced transthoracic harmonic echo Doppler. Eur. Heart J. 2009; 30: 1797–1806. DOI: 10.1093/eurheartj/ehp163.</mixed-citation><mixed-citation xml:lang="en">Caiati C., Zedda N., Cadeddu M., Chen L., Montaldo C., Iliceto S., Lepera M.E., Favale S. Detection, location, and severity assessment of left anterior descending coronary artery stenoses by means of contrast-enhanced transthoracic harmonic echo Doppler. Eur. Heart J. 2009; 30: 1797–1806. DOI: 10.1093/eurheartj/ehp163.</mixed-citation></citation-alternatives></ref><ref id="cit30"><label>30</label><citation-alternatives><mixed-citation xml:lang="ru">Caiati C., Montaldo C., Zedda N., Bina A., Iliceto S. New noninvasive method for coronary flow reserve assessment: contrast-enhanced transthoracic second harmonic echo Doppler. Circulation. 1999; 99 (6): 771–778.</mixed-citation><mixed-citation xml:lang="en">Caiati C., Montaldo C., Zedda N., Bina A., Iliceto S. New noninvasive method for coronary flow reserve assessment: contrast-enhanced transthoracic second harmonic echo Doppler. Circulation. 1999; 99 (6): 771–778.</mixed-citation></citation-alternatives></ref><ref id="cit31"><label>31</label><citation-alternatives><mixed-citation xml:lang="ru">Caiati C., Montaldo C., Zedda N., Montisci R., Ruscazio M., Lai G., Cadeddu M., Meloni L., Iliceto S. Validation of a new noninvasive method (contrast-enhanced transthoracic second harmonic echo Doppler) for the evaluation of coronary flow reserve: comparison with intracoronary Doppler flow wire. J. Am. Coll. Cardiol. 1999; 34: 1193–1200.</mixed-citation><mixed-citation xml:lang="en">Caiati C., Montaldo C., Zedda N., Montisci R., Ruscazio M., Lai G., Cadeddu M., Meloni L., Iliceto S. Validation of a new noninvasive method (contrast-enhanced transthoracic second harmonic echo Doppler) for the evaluation of coronary flow reserve: comparison with intracoronary Doppler flow wire. J. Am. Coll. Cardiol. 1999; 34: 1193–1200.</mixed-citation></citation-alternatives></ref><ref id="cit32"><label>32</label><citation-alternatives><mixed-citation xml:lang="ru">Takeuchi M., Ogawa K., Wake R., Takise H., Miyazaki C., Otani S., Sakamoto K., Yoshikawa J. Measurement of coronary flow velocity reserve in the posterior descending coronary artery by contrast-enhanced transthoracic Doppler echocardiography. J. Am. Soc. Echocardiogr. 2004; 17 (1): 21–27.</mixed-citation><mixed-citation xml:lang="en">Takeuchi M., Ogawa K., Wake R., Takise H., Miyazaki C., Otani S., Sakamoto K., Yoshikawa J. Measurement of coronary flow velocity reserve in the posterior descending coronary artery by contrast-enhanced transthoracic Doppler echocardiography. J. Am. Soc. Echocardiogr. 2004; 17 (1): 21–27.</mixed-citation></citation-alternatives></ref><ref id="cit33"><label>33</label><citation-alternatives><mixed-citation xml:lang="ru">Бощенко А.А. Комплексная неинвазивная ультразвуковая оценка коронарного кровотока и коронарного резерва у больных ишемической болезнью сердца: Дис. … д-ра мед. наук. Томск, 2014. 311 с.</mixed-citation><mixed-citation xml:lang="en">Boshchenko A.A. Complex non-invasive ultrasound assessment of coronary blood flow and coronary reserve in patients with ischemic heart disease: Diss. … doct. med. nauk. Tomsk, 2014. 311 p. (In Russian)</mixed-citation></citation-alternatives></ref><ref id="cit34"><label>34</label><citation-alternatives><mixed-citation xml:lang="ru">Krzanowski M., Bodzoń W., Dimitrow P.P. Imaging of all three coronary arteries by transthoracic echocardiography. An illustrated guide [Electronic resource]. Cardiovasc. Ultrasound. 2003; 1. URL: http://www.cardiovascularultrasound.com/content/1/1/16. (дата обращения 17.11.2017).</mixed-citation><mixed-citation xml:lang="en">Krzanowski M., Bodzoń W., Dimitrow P.P. Imaging of all three coronary arteries by transthoracic echocardiography. An illustrated guide [Electronic resource]. Cardiovasc. Ultrasound. 2003; 1. URL: http://www.cardiovascularultrasound.com/content/1/1/16. (дата обращения 17.11.2017).</mixed-citation></citation-alternatives></ref><ref id="cit35"><label>35</label><citation-alternatives><mixed-citation xml:lang="ru">Kini A.S. Coronary angiography, lesion classification and severity assessment. Cardiol. Clin. 2006; 24: 153–162.</mixed-citation><mixed-citation xml:lang="en">Kini A.S. Coronary angiography, lesion classification and severity assessment. Cardiol. Clin. 2006; 24: 153–162.</mixed-citation></citation-alternatives></ref><ref id="cit36"><label>36</label><citation-alternatives><mixed-citation xml:lang="ru">Czernin J., Muller P., Chan S., Brunken R.C., Porenta G., Krivokapich J., Chen K., Chan A., Phelps M.E., Schelbert H.R. Influence of age and hemodynamics on myocardial blood flow and flow reserve. Circulation. 1993; 88: 62–69.</mixed-citation><mixed-citation xml:lang="en">Czernin J., Muller P., Chan S., Brunken R.C., Porenta G., Krivokapich J., Chen K., Chan A., Phelps M.E., Schelbert H.R. Influence of age and hemodynamics on myocardial blood flow and flow reserve. Circulation. 1993; 88: 62–69.</mixed-citation></citation-alternatives></ref><ref id="cit37"><label>37</label><citation-alternatives><mixed-citation xml:lang="ru">Di Mario C., Meneveau N., Gil R., De Jaegere P., De Feyter P.J., Slager C.J., Roelandt J.R., Serruys P.W. Maximal blood flow velocity in severe coronary stenoses measured with a Doppler guide-wire. Limitations for the application of the continuity equation in the assessment of stenosis severity. Am. J. Cardiol. 1993; 71: 54D-61D.</mixed-citation><mixed-citation xml:lang="en">Di Mario C., Meneveau N., Gil R., De Jaegere P., De Feyter P.J., Slager C.J., Roelandt J.R., Serruys P.W. Maximal blood flow velocity in severe coronary stenoses measured with a Doppler guide-wire. Limitations for the application of the continuity equation in the assessment of stenosis severity. Am. J. Cardiol. 1993; 71: 54D-61D.</mixed-citation></citation-alternatives></ref><ref id="cit38"><label>38</label><citation-alternatives><mixed-citation xml:lang="ru">Di Carli M., Czernin J., Hoh C.K., Gerbaudo V.H., Brunken R.C., Huang S.C., Phelps M.E., Schelbert H.R. Relation among stenosis severity, myocardial blood flow, and flow reserve in patients with coronary artery disease. Circulation. 1995; 91: 1944–1951.</mixed-citation><mixed-citation xml:lang="en">Di Carli M., Czernin J., Hoh C.K., Gerbaudo V.H., Brunken R.C., Huang S.C., Phelps M.E., Schelbert H.R. Relation among stenosis severity, myocardial blood flow, and flow reserve in patients with coronary artery disease. Circulation. 1995; 91: 1944–1951.</mixed-citation></citation-alternatives></ref><ref id="cit39"><label>39</label><citation-alternatives><mixed-citation xml:lang="ru">Chamuleau S.A., Meuwissen M., van Eck-Smit B.L., Koch K.T., De Jong A., De Winter R.J., Schotborgh C.E., Bax M., Verberne H.J., Tijssen J.G., Piek J.J. Fractional flow reserve, absolute and relative coronary blood flow velocity reserve in relation to the results of technetium99m sestamibi single-photon emission computed tomography in patients with two-vessel coronary artery disease. J. Am. Coll. Cardiol. 2001; 37 (5): 1316–1322.</mixed-citation><mixed-citation xml:lang="en">Chamuleau S.A., Meuwissen M., van Eck-Smit B.L., Koch K.T., De Jong A., De Winter R.J., Schotborgh C.E., Bax M., Verberne H.J., Tijssen J.G., Piek J.J. Fractional flow reserve, absolute and relative coronary blood flow velocity reserve in relation to the results of technetium99m sestamibi single-photon emission computed tomography in patients with two-vessel coronary artery disease. J. Am. Coll. Cardiol. 2001; 37 (5): 1316–1322.</mixed-citation></citation-alternatives></ref><ref id="cit40"><label>40</label><citation-alternatives><mixed-citation xml:lang="ru">Бощенко А.А., Врублевский А.В., Карпов Р.С. Трансторакальное ультразвуковое исследование магистральных коронарных артерий: методические аспекты, возможности, ограничения. Ультразвуковая и функциональная диагностика. 2008; 6: 60–75.</mixed-citation><mixed-citation xml:lang="en">Boshchenko A.A., Vrublevsky A.V., Karpov R.S. Transthoracic echocardiography in the assessment of main coronary arteries: methodological aspects, potentials, limitations. Ultrasound and Functional Diagnostics. 2008; 6: 60–75. (In Russian)</mixed-citation></citation-alternatives></ref><ref id="cit41"><label>41</label><citation-alternatives><mixed-citation xml:lang="ru">Kim H.K., Kim Y.J., Sohn D.W., Park Y.B., Choi Y.S. Transthoracic echocardiographic evaluation of coronary flow reserve in patients with hypertrophic cardiomyopathy. Int. J. Cardiol. 2004; 94: 167–171.</mixed-citation><mixed-citation xml:lang="en">Kim H.K., Kim Y.J., Sohn D.W., Park Y.B., Choi Y.S. Transthoracic echocardiographic evaluation of coronary flow reserve in patients with hypertrophic cardiomyopathy. Int. J. Cardiol. 2004; 94: 167–171.</mixed-citation></citation-alternatives></ref><ref id="cit42"><label>42</label><citation-alternatives><mixed-citation xml:lang="ru">Лелюк В.Г., Лелюк С.Э. Ультразвуковая ангиология. М.: Реальное время, 2007. 398 с.</mixed-citation><mixed-citation xml:lang="en">Lelyuk V.G., Lelyuk S.E. Ultrasound angiology. Moscow: Realnoe vremya, 2007. 398 p. (In Russian)</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
