<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">medvis</journal-id><journal-title-group><journal-title xml:lang="ru">Медицинская визуализация</journal-title><trans-title-group xml:lang="en"><trans-title>Medical Visualization</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1607-0763</issn><issn pub-type="epub">2408-9516</issn><publisher><publisher-name>RDS-Media Ltd.</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">medvis-22</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>МОЛОЧНАЯ ЖЕЛЕЗА</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>BREAST</subject></subj-group></article-categories><title-group><article-title>Виртуальная сонография молочной железы. Опыт клинического применения</article-title><trans-title-group xml:lang="en"><trans-title>Virtual Breast Sonography. Results of Clinical Application</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Якобс</surname><given-names>Ольга Эдмундовна</given-names></name><name name-style="western" xml:lang="en"><surname>Yakobs</surname><given-names>Olga Edmundovna</given-names></name></name-alternatives><email xlink:type="simple">mnioi@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Каприн</surname><given-names>Андрей Дмитриевич</given-names></name><name name-style="western" xml:lang="en"><surname>Kaprin</surname><given-names>Andrey Dmitrievich</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Рожкова</surname><given-names>Надежда Ивановна</given-names></name><name name-style="western" xml:lang="en"><surname>Rozhkova</surname><given-names>Nadezhda Ivanovna</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Мазо</surname><given-names>Михаил Львович</given-names></name><name name-style="western" xml:lang="en"><surname>Mazo</surname><given-names>Michail L’vovich</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Микушин</surname><given-names>Сергей Юрьевич</given-names></name><name name-style="western" xml:lang="en"><surname>Mikushin</surname><given-names>Sergey Yurjevich</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГБУ “МНИОИ им. П.А. Герцена” Министерства здравоохранения России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>PA. Herzen Moscow Oncology Research Institute</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>Поликлиника ОАО “Газпром”</institution><country>Россия</country></aff><aff xml:lang="en"><institution>“Gazprom” Clinic</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2014</year></pub-date><pub-date pub-type="epub"><day>28</day><month>04</month><year>2014</year></pub-date><volume>0</volume><issue>2</issue><fpage>22</fpage><lpage>32</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Якобс О.Э., Каприн А.Д., Рожкова Н.И., Мазо М.Л., Микушин С.Ю., 2014</copyright-statement><copyright-year>2014</copyright-year><copyright-holder xml:lang="ru">Якобс О.Э., Каприн А.Д., Рожкова Н.И., Мазо М.Л., Микушин С.Ю.</copyright-holder><copyright-holder xml:lang="en">Yakobs O.E., Kaprin A.D., Rozhkova N.I., Mazo M.L., Mikushin S.Y.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://medvis.rdsmedia.ru/jour/article/view/22">https://medvis.rdsmedia.ru/jour/article/view/22</self-uri><abstract><p>Цель: оценить диагностическую эффективность автоматизированного УЗ-сканера всего объема молочных желез (ABVS - the automated breast volume scanner) ACUSON S2000 (Siemens, Германия). Материал и методы. Обследовано 97 пациентов (n=100), из них по данным комплексного лучевого обследования патологические образования в молочных железах не были выявлены (BI-RADS 1) у 27, с отчетливо доброкачественными образованиями (BI-RADS 2) было 18, патоморфологически подтвержден рак молочной железы (РМЖ) (BI-RADS 5) - у 29. Все данные сканирования были оценены независимым экспертом - лучевым диагностом на специальной просмотровой станции без предварительной дополнительной информации о каждой пациентке. Результаты. Чувствительность метода автоматизированного сканирования в выявлении патологии молочных желез составила 100%, диагностическая точность ABVS - 88%. Независимый эксперт установил диагноз РМЖ молочной железы в 26 (90%) случаях из 29. По результатам автоматизированного сканирования молочных желез в 66 (66%) случаях было рекомендовано дообследование с применением комплекса лучевых методов. Гипердиагностика составила 24%. Таким образом, специфичность ABVS-обследования была равна 40%. Выводы. Учитывая тот факт, что ни один из случаев РМЖ не был пропущен, первый опыт использования ABVS показал обнадеживающие результаты и необходимость в дальнейших клинических испытаниях автоматизированной системы сканирования молочных желез.</p></abstract><trans-abstract xml:lang="en"><p>The aim: to evaluate the diagnostic effectiveness the automated breast volume scanner (ABVS) ACUSON S2000 (Siemens, Germany). Material and methods: The volume data sets were collected from 97 patients and a database containing 27 women with no detectable lesions in multimodal examination (BI-RADS 1), 18 women with clearly benign lesions (BI-RADS2), and 29 women with known breast cancer (BI-RADS5) was created. An independent examiner evaluated all the ABVS data on a separate workstation without any prior knowledge of the patients’ histories. Results. The diagnostic accuracy for the experimental ABVS was estimated as 88%. The independent examiner detected all breast cancers in the volume data resulting in a calculated sensitivity of 100%. After the ABVS examination, there were a high number of requests for further examination in 66%. Over-diagnosis was estimated 24 %. Conclusion. The specificity was 40%. Given the fact that during the application of ABVS no breast cancer was missed - the ABVS must still be regarded as an experimental technique for breast ultrasound, which definitely needs to undergo further evaluation studies.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>УЗИ молочных желез</kwd><kwd>автоматизированное ультразвуковое сканирование молочных желез</kwd><kwd>рак молочной железы</kwd><kwd>3D-реконструкция</kwd><kwd>breast cancer</kwd><kwd>automated breast ultrasound</kwd><kwd>breast ultrasound</kwd><kwd>3D-reconstruction</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Лучевая диагностика в маммологии: Руководство для врачей; Под ред. Н.И. Рожковой. М.: СИМК, 2013. 121 с.</mixed-citation><mixed-citation xml:lang="en">Лучевая диагностика в маммологии: Руководство для врачей; Под ред. Н.И. Рожковой. М.: СИМК, 2013. 121 с.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Цифровая маммологическая клиника. Современные технологии; Под ред. Н.И. Рожковой. М.: СИМК, 2012. 157 с.</mixed-citation><mixed-citation xml:lang="en">Цифровая маммологическая клиника. Современные технологии; Под ред. Н.И. Рожковой. М.: СИМК, 2012. 157 с.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Maturo V.G., Zusmer N.R., Gilson A.J. et al. Ultrasound of the whole breast utilizing a dedicated automated breast scanner. Radiology. 1980; 137: 457-463.</mixed-citation><mixed-citation xml:lang="en">Maturo V.G., Zusmer N.R., Gilson A.J. et al. Ultrasound of the whole breast utilizing a dedicated automated breast scanner. Radiology. 1980; 137: 457-463.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Egan R.L., Egan K.L. Automated water-pathfull-breast sonography: correlation with histology of 176 solid lesions. Am. J. Roentgenol. 1984; 143: 499-507.</mixed-citation><mixed-citation xml:lang="en">Egan R.L., Egan K.L. Automated water-pathfull-breast sonography: correlation with histology of 176 solid lesions. Am. J. Roentgenol. 1984; 143: 499-507.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Wenkel E., Heckmann M., Heinrich M. et al. Automated breast ultrasound: lesion detection and BI-RADS classification - a pilot study. Rofo. 2008; 180: 804-808.</mixed-citation><mixed-citation xml:lang="en">Wenkel E., Heckmann M., Heinrich M. et al. Automated breast ultrasound: lesion detection and BI-RADS classification - a pilot study. Rofo. 2008; 180: 804-808.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Kelly K.M., Dean J., Lee S.J., Comulada W.S. Breast cancer detection: radiologists' performance using mammography with and without automated whole-breast ultrasound. Eur. Radiol. 2010; 20: 2557-2564.</mixed-citation><mixed-citation xml:lang="en">Kelly K.M., Dean J., Lee S.J., Comulada W.S. Breast cancer detection: radiologists' performance using mammography with and without automated whole-breast ultrasound. Eur. Radiol. 2010; 20: 2557-2564.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Wojcinski S., Farrokh A., Hille U. et al. Automated Breast Volume Scanner (ABVS): initial experiences in lesion detection compared with conventional handheld B-mode ultrasound: a pilot study of 50 cases. Int. J. Womens Health. 2011; 3: 337-346.</mixed-citation><mixed-citation xml:lang="en">Wojcinski S., Farrokh A., Hille U. et al. Automated Breast Volume Scanner (ABVS): initial experiences in lesion detection compared with conventional handheld B-mode ultrasound: a pilot study of 50 cases. Int. J. Womens Health. 2011; 3: 337-346.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Wang Z.L., Xu J.H., Li J.L. et al. Comparison of automated breast volume scanning to hand-held ultrasound and mammography. Radiol. Med. 2012; 117 (8): 1287-1293.</mixed-citation><mixed-citation xml:lang="en">Wang Z.L., Xu J.H., Li J.L. et al. Comparison of automated breast volume scanning to hand-held ultrasound and mammography. Radiol. Med. 2012; 117 (8): 1287-1293.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Kim H., Cha J.H., Oh H.Y. et al. Comparison of conventional and automated breast volume ultrasound in the description and characterization of solid breast masses based on BI-RADS features. J. Breast Cancer. 2013; 16 (3): 329-334.</mixed-citation><mixed-citation xml:lang="en">Kim H., Cha J.H., Oh H.Y. et al. Comparison of conventional and automated breast volume ultrasound in the description and characterization of solid breast masses based on BI-RADS features. J. Breast Cancer. 2013; 16 (3): 329-334.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Маммология: Национальное руководство; Под ред. В.П. Харченко, Н.И. Рожковой. М.: ГЭОТАР-Медиа, 2009. 324 с.</mixed-citation><mixed-citation xml:lang="en">Маммология: Национальное руководство; Под ред. В.П. Харченко, Н.И. Рожковой. М.: ГЭОТАР-Медиа, 2009. 324 с.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Mendelson E.B., Baum J.K., Berg W.A. et al. BI-RADS: Ultrasound. In: Breast Imaging Reporting and Data System: ACR BI-RADS - Breast Imaging Atlas. Eds D'Orsi C.J., Mendelson E.B., Ikeda D.M. et al. Reston, VA: American College of Radiology, 2003. 345 p.</mixed-citation><mixed-citation xml:lang="en">Mendelson E.B., Baum J.K., Berg W.A. et al. BI-RADS: Ultrasound. In: Breast Imaging Reporting and Data System: ACR BI-RADS - Breast Imaging Atlas. Eds D'Orsi C.J., Mendelson E.B., Ikeda D.M. et al. Reston, VA: American College of Radiology, 2003. 345 p.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Kusano A.S., Trichopoulos D., Terry K.L. et al. A prospective study of breast size and premenopausal breast cancer incidence. Int. J. Cancer. 2006; 118: 2031-2034.</mixed-citation><mixed-citation xml:lang="en">Kusano A.S., Trichopoulos D., Terry K.L. et al. A prospective study of breast size and premenopausal breast cancer incidence. Int. J. Cancer. 2006; 118: 2031-2034.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Wright M.C. Graphical analysis of bra size calculation procedures. Int. J. Cloth. Sci. Technol. 2002; 14: 41-45.</mixed-citation><mixed-citation xml:lang="en">Wright M.C. Graphical analysis of bra size calculation procedures. Int. J. Cloth. Sci. Technol. 2002; 14: 41-45.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Chae E.Y., Shin H.J., Kim H.J. Diagnostic performance of automated breast ultrasound as a replacement for a handheld second-lookultrasound for breast lesions detected initially on magnetic resonance imaging. Ultrasound Med. Biol. 2013; 39 (12): 2246-2254.</mixed-citation><mixed-citation xml:lang="en">Chae E.Y., Shin H.J., Kim H.J. Diagnostic performance of automated breast ultrasound as a replacement for a handheld second-lookultrasound for breast lesions detected initially on magnetic resonance imaging. Ultrasound Med. Biol. 2013; 39 (12): 2246-2254.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Wojcinski S., Gyapong S., Farrokh A. et al. Diagnostic performance and inter-observer concordance in lesion detection with the automated breast volume scanner (ABVS). BMC Med. Imaging. 2013; 13: 36.</mixed-citation><mixed-citation xml:lang="en">Wojcinski S., Gyapong S., Farrokh A. et al. Diagnostic performance and inter-observer concordance in lesion detection with the automated breast volume scanner (ABVS). BMC Med. Imaging. 2013; 13: 36.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Chen L., Chen Y., Diao X.H. Comparative study of automated breast 3-D ultrasound and handheld B-mode ultrasound for differentiation of benign and malignant breast masses. Ultrasound Med. Biol. 2013; 39 (10): 1735-1742.</mixed-citation><mixed-citation xml:lang="en">Chen L., Chen Y., Diao X.H. Comparative study of automated breast 3-D ultrasound and handheld B-mode ultrasound for differentiation of benign and malignant breast masses. Ultrasound Med. Biol. 2013; 39 (10): 1735-1742.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Skaane P., Gullien R., Eben E.B. Interpretation of automated breast ultrasound (ABUS) with and without knowledge of mammography: a reader performance study. Acta Radiol. 2014 Mar 28; [Epub ahead of print].</mixed-citation><mixed-citation xml:lang="en">Skaane P., Gullien R., Eben E.B. Interpretation of automated breast ultrasound (ABUS) with and without knowledge of mammography: a reader performance study. Acta Radiol. 2014 Mar 28; [Epub ahead of print].</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Prosch H., Halbwachs C., Strobl C. Automated breast ultrasound vs. handheld ultrasound: BI-RADS classification, duration of the examination and patient comfort. Ultraschall Med. 2011; 32 (5): 504-510.</mixed-citation><mixed-citation xml:lang="en">Prosch H., Halbwachs C., Strobl C. Automated breast ultrasound vs. handheld ultrasound: BI-RADS classification, duration of the examination and patient comfort. Ultraschall Med. 2011; 32 (5): 504-510.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Kim Y.W., Kim S.K., Youn H.J. et al. The clinical utility оf automated breast volume scanner: a pilot study of 139 cases. J. Breast Cancer. 2013; 16 (3): 329-334.</mixed-citation><mixed-citation xml:lang="en">Kim Y.W., Kim S.K., Youn H.J. et al. The clinical utility оf automated breast volume scanner: a pilot study of 139 cases. J. Breast Cancer. 2013; 16 (3): 329-334.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
